Description:
HSI Gas Ignition Control - replacement for popular models, including Honeywell S8910U-1000
Specifications:
Input Voltage: 120 & 24 VAC, 60Hz
- HSI: 120V, 5A max
- Valve: 24V, 2A max
- Total: 24V Load = 0.4 + valve load
Pre-purge Time: 32 seconds
Trial Time: 4 or 7 sec (switch selectable)
Ignition Trials to Lockout: 1 or 3 (switch selectable)
Flame Sense: Single rod or dual rod
Gas Type: Natural or LP Weight/Dimensions:
Weight: 0.4
Height: 1.625
Width: 5.375
Length: 4
Low cost replacement HSI control for Honeywell, Robertshaw and White Rodgers
Single/Dual rod sensing capabilities
For gas fired furnaces, boilers and other heating appliances
Switch selectable lockout times, ignition trials
Works with both Natural and LP systems
Diagnostic LED to aid in troubleshooting
Replaces part #'s:
Honeywell: S8910U-1000
Robertshaw: HS780
White Rodgers: 50E47, 50F47